서비스 시간: 월요일 ~ 금요일 9:00-18:00
BDA-SSTRI1 - BDA-SSTRI1 CARLO GAVAZZI FUN selected parameters Temperature Control MOU Decentralised SUP Bus powered Salli..
재고 있음 인기 제품

BDA-SSTRI1

BDA-SSTRI1 CARLO GAVAZZI FUN selected parameters Temperature Control MOU Decentralised SUP Bus powered Salli..

$0.00USD
4620개 재고
공급업체 정보
CARLO GAVAZZI
CARLO GAVAZZI
제품: 10094
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원

제품 설명

More details
주요 기능
  • 산업 등급 품질
  • RoHS 준수
  • CE 인증
  • 1년 보증

기술 세부 정보

Solid State Relay OutputBDA-SSTRI1Small sized single solid state relay outputLoad: 10 WattPowered by smart-houseAddress coding by BGP-COD-BAT Low power consumptionGENERAL SPECIFICATIONSFail-safe modeIn case of interruption of the smart-house connection, the channel will be forced into a specific optional status aseither active high or active low. EnvironmentPollution degree 3 (IEC 60664)Operation temperature -20° to +50°C (-4° to 122°F) Storage temperature -50° to +85°C (-58° to 185°F)Humidity (non-condensing)20 to 80% HousingMaterial Noryl GFN 1, blackDimensions (h x w x d)26 x 39 x 17 mmOUTPUT SPECIFICATIONSOutput 1 solid state relay (Triac) Maximum load10 Watt / 50 mA Minimum load (recommended)5 mA/230 VACResponse time1 pulse trainSUPPLY SPECIFICATIONSSupplied by smart-houseCurrent consumption < 3 mA Power-on delayTyp. 2 sWIRE CONNECTIONSBus: White = smart-house signal, D+ Black= smart-house negative, D-Output:Brown= Solid state relay - LinOrange = Solid state relay - LoutBus wires:2 x 0,75 mm2,250 V isolation, single core, 150 mmOutput wires:2 x 1,5 mm2 ,250 V isolation, single core, 150 mmINSULATION VOLTAGELive parts - smart-house4 kVAC rms (6 mm) Enclosure - Live parts2 kVAC rms (3 mm) Enclosure - smart-house2 kVAC rms (3 mm)MODE OF OPERATIONThe smart-house decentral receiver has one NO solid state output. The module is especially designed for the use in building automation applications. It is further on developed to control heat valves in a heating system together with the temperature unit BFW-TEMDIS or BOW-TEMDIS. The compact size of the module makes it possible to fit it in a junction box or directly behind a power outlet.The output address and fail-polarity may be coded by means of the code programmer BGP-COD-BAT, with GAP-THP-CAB cable.Upon loss of smart-house carrier the output goes to the predefined fail-polarity.TYPE SELECTIONSupplyOrdering no.Smart-house BDA-SSTRI1ACCESSORIESProgramming cableto BGP-COD-BAT GAP-TPH-CABWIRING DIAGRAMDIMENSIONSWhite BlackOrange BrownDS + D -LoutOut 1Lin39Specifications are subject to change without notice (20.09.2007) - A product of the CARLO GAVAZZI Group

제품 문서

데이터시트

기술 사양 및 성능 데이터

사용자 매뉴얼

설치 및 운영 가이드

Top