Compact three-phase power transducer, Din rail, basic version
주요 기능
  • 산업 등급 품질
  • RoHS 준수
  • CE 인증
  • 1년 보증

기술 세부 정보

Energy Management Compact Power Transducer Type CPT-DIN “Basic version”• RS232 serial port on request• Alarms (only from serial communication port) VLN, An• Class 2 (active energy)• Class 3 (reactive energy)• Accuracy ±0.5 F.S. (current/voltage)• Compact Power transducer• Instantaneous variables data format: 4 digit• Energies data format: 8+1 digit• System variables and phase measurements: W, Wdmd, Wdmdmax, var, VA, VAdmd, PF, V, A, An, Admd, Amax, Admd max, Hz• Energy measurements: kWh and kvarh• Hour counter (5+2 DGT)• TRMS meas. of distorted sine waves (voltages/currents)• Power supply: 90 to 260VAC/DC and 18 to 60VAC/DC• Protection degree (front): IP20• Dimensions: 45x83.5x98.5mm• RS422/485 serial portProduct DescriptionHow to order CPT-DIN AV5 3 HS1 BX3-phase compact power transducer. Particularly rec- ommended for the measure- ments of the main electrical variables.Housing for DIN-rail mount-ing, protection degree IP20 as standard, and RS485 or RS232 serial port. Parameters programmable by means of CptBSoft.Model Range code SystemPower supply Outputs OptionHow to orderCptBSoft-kitType SelectionCptBSoft: software to program the working parameters of the transducer and to read the energy and the instanta- neous variables. The kit includes the communication cable.Range codesAV5: 400/(690)VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 VAV6: 120/(208)VL-L/5(6)AAC VL-N: 45 V to 145 VVL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6ASystem3 :1, 2 or 3-phase, unbalanced and balanced load, with or without neutral1 :1-3-phase, balanced load (*)Power supplyL: 18 to 60VAC/DCH: 90 to 260VAC/DC(*)Pay attention:the 3-phase measurement is carried out as one current and one phase to neutral voltage measurement.OutputsS1: RS485 portS2: RS232 portOptionsBX: Basic featuresInputspecificationsRated inputsCurrent3 (current transformers) Voltage4Accuracy (RS485/RS232)with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%)1150W-VA-var, FS:230VLN,400VLL AV6: 285W-VA-var, FS: 57VLN, 100VLLCurrent 0.25 to 6A: ±(0.5% FS +1DGT)0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current0.25 to 6A: ±(1.5% FS +1DGT)0.09Ato0.25A:±(1.5%FS+7DGT)Phase-phase voltage ±(1.5% FS + 1DGT) Phase-neutral voltage ±(0.5% FS + 0.1DGT) Active and Apparent power,0.25 to 6A: ±(1%FS +1DGT)0.03A to 0.25A: ±(1%FS+5DGT)Reactive power 0.25 to 6A: ±(2% FS +1DGT)0.03A to 0.25A: ±(2% FS +5DGT) Active energy Class 2 (I start up: 30mA) Reactive energyClass 3 (I start up: 30mA) Frequency±0.1Hz (48 to 62Hz)Additional errorsHumidity≤0.3% FS, 60% to 90% RHTemperature drift≤ 200ppm/°CSampling rate1400 samples/s @ 50Hz1700 samples/s @ 60HzMeasurement refresh time 700msMeasurement formatInstantaneous variables4 DGT (Max indication: 9999) Energies 9 DGT (Max indication:999 999 99.9)Hour counter 7 DGT (Max. indication:9 999 9.99)Specifications are subject to change without noticeCPT-DINBDS080610 1

제품 문서

데이터시트

기술 사양 및 성능 데이터

사용자 매뉴얼

설치 및 운영 가이드

Top