| 매개변수 | 가치 |
|---|---|
| GTIN | 4055626112633 |
| 주문키 | 1417382 |
| 카탈로그 페이지 | Page 563 (C-2-2017) |
| 포장 단위 | 2 pc |
| 원산지 | PL (Poland) |
| 관세 번호 | 85366990 |
| (주변 환경 조건) | 16 mm (40 mm²) |
| 최소 주문 수량 | 2 pc |
| 연락처 자료 (일반) | Copper alloy |
| 너비 (주요 상업 데이터) | 34.4 mm |
| (표준 및 규정) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| 높이 (주요 상업 데이터) | 54.6 mm |
| 길이 (주요 상업 데이터) | 29.3 mm |
| (기계적 특성) | The axial screw connection must be established using a 5 mm Allen key (for stranded conductors only) |
| 연결 프로필(치수) | PE |
| 참고 (기계적 특성) | For HEAVYCON HC-B6 to B48 housing (housing height: min. 72 mm), HC-M-B..-MF-... module carrier frame required, axial connection for 5 mm Allen key |
| 색상(기계적 특성) | light gray |
| 접촉 캐리어 재료(일반) | PC |
| 접촉면 재질 (일반) | Ag |
| 시리즈(기계적 특성) | HC-M-HS |
| 개당 중량 (포장 제외) | 92.550 g |
| 접촉 직경(주변 환경 조건) | 9.5 mm |
| 육각형 소켓 (주변 환경 조건) | WAF 5 |
| 중국 RoHS(표준 및 규정) | Environmentally Friendly Use Period = 50 |
| REACh SVHC(표준 및 규정) | Lead 7439-92-1 |
| 조임 토크(주변 환경 조건) | 8 Nm (25 mm² ... 70 mm²) |
| 연결(기계적 특성) | Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
| 접촉 유형(기계적 특성) | turned |
| 최소 주택 높이(주변 환경 조건 기준) | 72 mm |
| 도체 단면적 (주변 환경 조건) | 25 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| 연결 방식 (기계적 특성) | Axial screw connection |
| 삽입/제거 주기(주변 환경 조건) | ≥ 500 |
| 연결 단면적 AWG (주변 환경 조건) | 10 ... 00 |
| 조립 설명서 (기계적 특성) | To ensure correct use, installation in housing with IP54 protection or better is required |
| 모듈 슬롯 개수 (기계적 특성) | 2 |
| UL 94에 따른 난연성 등급(재료 데이터) | V0 |
| 절연체를 포함한 전선 직경 (주변 환경 조건) | 12 mm (25 mm²) |
| 주변 온도(작동) (전기적 특성) | -40 °C ... 125 °C |
| 개별 전선의 피복 벗기기 길이 (주변 환경 조건) | 16 mm |
| UL 94에 따른 난연성 등급(기계적 특성) | V0 |