HC-M-02-MOD-ST - HC-M-02-MOD-ST 1679346 PHOENIX CONTACT HEAVYCON contact insert module, male, 2-pos., axial screw connection
재고 있음 인기 제품

HC-M-02-MOD-ST

HC-M-02-MOD-ST 1679346 PHOENIX CONTACT HEAVYCON contact insert module, male, 2-pos., axial screw connection

$0.00USD
4329개 재고
주요 사양
:Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
너비:34.2 mm
키:41.8 mm
길이:14.6 mm
공급업체 정보
제품: 0
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원

기술 사양

매개변수가치
Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly.
너비34.2 mm
41.8 mm
길이14.6 mm
시리즈HC-M-02
일반적인For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required
애플리케이션Power
제품 유형Modular contact insert
조립 참고 사항- Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage.
정격 전류40 A
접촉 재료Copper alloy
육각형 소켓SW 2
연락처1 - 2
조임 토크1.5 Nm (2.5 mm² ... 4 mm²)
연결 프로필2
오염 정도3
치수 도면
직위 수2
정격 서지 전압8 kV
과전압 범주III
연결 기술Axial screw connection
정격 전압(III/3)1000 V
모듈 슬롯 수1
도체 단면적2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used)
접촉 캐리어 재료PC
접촉면 재질Ag
삽입/제거 주기≥ 500
연결 단면 AWG12 ... 10
주변 온도(작동)-40 °C ... 125 °C
표준에 따른 연결IEC / EN
UL 94에 따른 난연성 등급V0
개별 전선의 피복 벗기기 길이8 mm +1 mm (for 6 mm²)

제품 설명

More details
주요 기능
  • 산업 등급 품질
  • RoHS 준수
  • CE 인증
  • 1년 보증

제품 문서