LDP1SA1B115-2 CARLO GAVAZZI Selected parameters LOOP NUMBER Single Loop Others LOOP NUMBER Single Loop Detec..
$0.00USD
3026개 재고
공급업체 정보
CARLO GAVAZZI
제품: 10094
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원
제품 설명
More details
주요 기능
산업 등급 품질
RoHS 준수
CE 인증
1년 보증
기술 세부 정보
Inductive Sensors Single Loop Detector Type LD with teach-in• Single loop detector• Automatically adjustment of detection level• Manual sensitivity for compensations of variations• Easy installation via 11 pin circular plug• Rated operational voltage:24 VAC/DC, 115 VAC or230 VAC• Pulse or presence relay output• Output 1A/250 VAC SPDT relay• LED indication for power, relay status and loop fault• Sensitivity boost – only LDP1• Selectable frequency – prevents cross-talkProduct DescriptionOrdering KeyLDP1 SA1B230-2Loopdetectorsfor detection of vehicles. The vehicle loop detector is designed to handle all parking, drive-through and access control applications for controlling doors, gates, barri- ers or fences.Type SelectionThe principleis based ona change in the inductance within the loop when a metal- lic object (vehicles) is passing. The microprocessor evaluates the changes.TypePlug mounting Loop inputs Function Adjustment OutputsRelay versionsPower supplyMountingRelay Ordering no. Ordering no. Ordering no.Supply: 24 VAC/DCSupply: 115 VACSupply: 230 VACSingle loopSPDT LDP1SA1BM24-2 LDP1SA1B115-2 LDP1SA1B230-2SpecificationsRated operational voltage (UB)Pin 2 & 9 230195 to 265 VAC, 45 to 65 Hz11598 to 132 VAC, 45 to 65 HzM24 19.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kVAC (rms)Rated impulse withstand voltage 4 kV (1.2/50 µs) (line/neutral)Rated operational powerAC supply 3 VAAC/DC supply 1.5 VA / 1.5 W Power on delay (tV)< 10 secTyp. 4 sec OutputsMinimum switching current10 mA @ 12 VRated insulation voltage 250 VAC (rms) (cont./elec.)Relay Rating (AgNi 90/10) µ (micro gap)Resistive loads AC1 1 A / 250 VAC (250 VA) DC1 1 A / 30 VDC (30 W)Mechanical life (typical) ≥15 x 106 operations@ 18’000 imp/hElectrical life (typical)AC1 > 250’000 operationsSensitivity8 sensitivity settings availableFrequency range 13 - 120 kHz Loop inductance15 - 1500 µH Operating frequency (f)Relay output1 HZResponse time 400 mSEnvironmentOvervoltage category III (IEC 60664)Degree of protection IP 20 /IEC 60529, 60947-1) Pollution degree2 (IEC 60664/60664A,60947-1)TemperatureOperating-20º to +70ºC (-4º to + 158ºF) Storage -50º to +85ºC (-58º to +185ºF)Housing material NORYL SE1, light greyWeightAC supply 150 gAC/DC supply 85 gApprovals UL508CE markingYesSpecifications are subject to change without notice (24.09.13) 1