NSO02DB24SA CARLO GAVAZZI Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Othe..
$0.00USD
4406개 재고
공급업체 정보
CARLO GAVAZZI
제품: 10094
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원
제품 설명
More details
주요 기능
산업 등급 품질
RoHS 준수
CE 인증
1년 보증
기술 세부 정보
Safety ModulesSafety Gate and Safety Magnetic SensorTypesNSO02D, NSO13DScrew, fixedScrew, detachable• Safety Category 4, Performance Level e, according to EN 13849-1• Safety Category 4 according to EN 954-1• Category 0 Emergency Stop (EN 60204-1)• Input type: 2 NO• 2 x 6 A NO safety outputs (NSO02D)• 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NSO13D)• Automatic / manual or monitored manual reset• Single / double channel operations• LED indication for outputs status and power supply ON• Connection by fixed or detachable terminals• For mounting on DIN-rail in accordance with DIN/EN 50022• 22.5 mm Euronorm housingProduct DescriptionOrdering KeyNSO0 2 D B24 S ASafety gateand safety magnetic sensor modules according to EN 60204-1, EN292-1/-2,EN418andEN1088.This family of safety module inSafetyCategory4,TypeSelectionPerformance Level e, includes fixed screw and detachable screw as well as automatic/manual or monitored manual restart versions.Housing Function Auxiliary outputs Safety outputs Safety category Power supply Terminals Start/Reset typeAuxiliary outputsSafetyoutputs Terminals Start/Reset type Supply: 24 VAC/DC2 NOScrew, fixedAutomatic / Manual N SO 0 2 D B24 S A2 NOScrew, fixedMonitored manualN SO 0 2 D B24 S C2 NOScrew, detachableAutomatic / Manual N SO 0 2 D B24 D A2 NOScrew, detachableMonitored manualN SO 0 2 D B24 D C1 NC3 NOScrew, fixedAutomatic / Manual N SO 1 3 D B24 S A1 NC3 NOScrew, fixedMonitored manualN SO 1 3 D B24 S C1 NC3 NOScrew, detachableAutomatic / Manual N SO 1 3 D B24 D A1 NC3 NOScrew, detachableMonitored manualN SO 1 3 D B24 D CTimeSpecificationOutput SpecificationDelay ON energisation < 150 ms Delay ON de-energisation< 30 ms Recovery time ≥ 30 ms Channel simultaneityduring outputs closingInfiniteInput operating to STARToperating delayNSO...C> 500 msInputSpecificationsFunction2 NO, voltage freeInput currentTerminals S11-S12 max 10 mA Terminals S21-S22 max 10 mAExternal contact resistanceTerminals S11-S12 max. 60ΩTerminals S21-S22 max. 60ΩSafety outputsCategory 4, PerformanceLevel e (EN 13849-1) NSO02D2 NO (13-14, 23-24) NSO13D3 NO (13-14, 23-24, 33-34)Auxilary outputNSO13D1 NC (41-42)Rated insulation voltage 250 VAC (rms)Contact ratings (AgSnO2)2 µm AuSafety outputsResistive loads AC1 6 A @ 230 VAC DC12 6 A @ 24 VDCSmall inductive loadsAC153 A @ 230 VAC DC13 2.5 A @ 24 VDCAuxiliary output 6A, 24 VAC/DCExternal contact fuseprotection5 A fast, 4 A slowMechanical life> 107 operations Electrical life> 105 operations Dielectric strengthDielectric voltage4 kVAC (rms)1Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network.27/09/12