서비스 시간: 월요일 ~ 금요일 9:00-18:00
TN-3000-212B - TN-3000-212B MEANWELL DC-AC Solar inverter with battery charger for stand alone solar systems, battery 12VDC..
재고 있음 인기 제품

TN-3000-212B

TN-3000-212B MEANWELL DC-AC Solar inverter with battery charger for stand alone solar systems, battery 12VDC..

$0.00USD
3482개 재고
공급업체 정보
MEANWELL
MEANWELL
제품: 6448
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원

제품 설명

More details
주요 기능
  • 산업 등급 품질
  • RoHS 준수
  • CE 인증
  • 1년 보증

기술 세부 정보

3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000series 3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000series3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000seriesFeatures : Features :Features : Sine wave output (THD<3%) Sine wave output (THD<3%)Sine wave output (THD<3%) High power up to 6000W High power up to 6000WHigh power up to 6000W U. P. S. mode and energy saving mode (selectable) U. P. S. mode and energy saving mode (selectable)U. P. S. mode and energy saving mode (selectable) High efficiency of up to 92% High efficiency of up to 92%High efficiency of up to 92% Power on-OFF switch Power on-OFF switchPower on-OFF switch Standby saving mode can be selectable Standby saving mode can be selectableStandby saving mode can be selectable Front Panel indicatorfor state of operation Front Panel indicatorfor state of operationFront Panel indicatorfor state of operation Thermostat-controlled cooling fan Thermostat-controlled cooling fanThermostat-controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature. Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature.Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature. / Output short / Input polarity reverse / Overload / AC circuit breaker / Output short / Input polarity reverse / Overload / AC circuit breaker/ Output short / Input polarity reverse / Overload / AC circuit breaker Application : home appliances, power tools, office and portable Application : home appliances, power tools, office and portableApplication : home appliances, power tools, office and portable equipment, motor vehicles, and yachts, etc ... equipment, motor vehicles, and yachts, etc ...equipment, motor vehicles, and yachts, etc ... Built in solar / AC charger Built in solar / AC chargerBuilt in solar / AC charger Computer-based monitoring software (Note.7) Computer-based monitoring software (Note.7)Computer-based monitoring software (Note.7) 3 years warranty 3 years warranty3 years warrantySPECIFICATION SPECIFICATIONSPECIFICATION MODEL MODELMODEL E13 E13E13TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 RATED POWER (Typ.)3000W RATED POWER (Typ.)3000WRATED POWER (Typ.)3000W MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cycles MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cyclesMAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cycles Factory setting set at 110VACFactory set to 230VAC Factory setting set at 110VACFactory set to 230VACFactory setting set at 110VACFactory set to 230VAC OUTPUT OUTPUTOUTPUT THE AC VOLTAGE THE AC VOLTAGEAC VOLTAGEFREQUENCY FREQUENCYFREQUENCY 100 / 110 / 115 / 120VACselectable by setting button S. W 100 / 110 / 115 / 120VACselectable by setting button S. W100 / 110 / 115 / 120VACselectable by setting button S. W 600.1 Hz 50/60 hz selectable by setting button S. W 600.1 Hz 50/60 hz selectable by setting button S. W600.1 Hz 50/60 hz selectable by setting button S. W 200 / 220 / 230 / 240VACselectable by setting button S. W 200 / 220 / 230 / 240VACselectable by setting button S. W200 / 220 / 230 / 240VACselectable by setting button S. W 500.1 Hz 50/60 hz selectable by setting button S. W 500.1 Hz 50/60 hz selectable by setting button S. W500.1 Hz 50/60 hz selectable by setting button S. W WAVEFORM of the Note.8True sine wave (THD<3%) WAVEFORM of the Note.8True sine wave (THD<3%)WAVEFORM of the Note.8True sine wave (THD<3%) AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.) AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.)AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.) INDICATOR ON THE FRONT PANEL INDICATOR ON THE FRONT PANELINDICATOR ON THE FRONT PANEL 3% 3%3% 10ms inverterby pass 10ms inverterby pass10ms inverterby pass Disabled by default. Load5W will switch to the standby mode Disabled by default. Load5W will switch to the standby modeDisabled by default. Load5W will switch to the standby mode The battery voltage level, output load level, saving mode, fault and operation status The battery voltage level, output load level, saving mode, fault and operation statusThe battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE BAT. VOLTAGEBAT. VOLTAGE 12V 12V12V 24V 24V24V 48V 48V48V 12V 12V12V 24V 24V24V 48V 48V48V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDCVOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) Note.4300A DC CURRENT (Typ.) Note.4300ADC CURRENT (Typ.) Note.4300A 21 ~ 30VDC 21 ~ 30VDC21 ~ 30VDC 150A 150A150A 42 ~ 60VDC 42 ~ 60VDC42 ~ 60VDC 75A 75A75A 10.5 ~ 15VDC 10.5 ~ 15VDC10.5 ~ 15VDC 300A 300A300A 21 ~ 30VDC 21 ~ 30VDC21 ~ 30VDC 150A 150A150A 42 ~ 60VDC 42 ~ 60VDC42 ~ 60VDC 75A 75A75A INPUT INPUTINPUT NO LOAD DISSIPATION (Typ.)10W @ standby saving mode NO LOAD DISSIPATION (Typ.)10W @ standby saving modeNO LOAD DISSIPATION (Typ.)10W @ standby saving mode Turn OFF MODE CURRENT consumption (Typ.) 1mA Turn OFF MODE CURRENT consumption (Typ.) 1mATurn OFF MODE CURRENT consumption (Typ.) 1mA EFFICIENCY (Typ.) Note.188% EFFICIENCY (Typ.) Note.188%EFFICIENCY (Typ.) Note.188% 90% 90%90% 91% 91%91% 89% 89%89% 91% 91%91% 92% 92%92% BATTERY TYPESOpen and sealed lead acid battery BATTERY TYPESOpen and sealed lead acid batteryBATTERY TYPESOpen and sealed lead acid battery FUSE FUSEFUSE 40A*12 40A*1240A*12 40A*6 40A*640A*6 20A*6 20A*620A*6 40A*12 40A*6 20*6 40A*12 40A*6 20*640A*12 40A*6 20*6 THE INPUT OF THE BATTERY THE INPUT OF THE BATTERYTHE INPUT OF THE BATTERY BAT. LOW ALARM Note.611.3 V BAT. LOW ALARM Note.611.3 VBAT. LOW ALARM Note.611.3 V 22.5 V 22.5 V22.5 V 45V 45V45V 11.3 V 22.5 V 45V 11.3 V 22.5 V 45V11.3 V 22.5 V 45V PROTECTIONBAT. LOW SHUTDOWNNote.610.5 V PROTECTIONBAT. LOW SHUTDOWNNote.610.5 VPROTECTIONBAT. LOW SHUTDOWNNote.610.5 V 21V 21V21V 42V 42V42V 10.5 V 21V42V 10.5 V 21V42V10.5 V 21V42V OUTPUT OUTPUTOUTPUT REVERSE POLARITY OVER TEMPERATURE OUTPUT SHORT REVERSE POLARITY OVER TEMPERATURE OUTPUT SHORTREVERSE POLARITY OVER TEMPERATURE OUTPUT SHORT By internal fuse open By internal fuse openBy internal fuse open 90 5 85 5 85 5 80 5 75 5 75 5 90 5 85 5 85 5 80 5 75 5 75 590 5 85 5 85 5 80 5 75 5 75 5 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recoverProtection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recoverProtection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec. 105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec.105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec. PROTECTIONOVER LOAD (Typ.) PROTECTIONOVER LOAD (Typ.)PROTECTIONOVER LOAD (Typ.)CIRCUIT BREAKER CIRCUIT BREAKERCIRCUIT BREAKER Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recoverProtection type : Shut down o/p voltage, re-power on to recover AC output: 40A, AC receptacle:15A AC output: 40A, AC receptacle:15AAC output: 40A, AC receptacle:15A AC output: 20A, AC receptacle: 15A AC output: 20A, AC receptacle: 15AAC output: 20A, AC receptacle: 15A GFCI PROCTECTION GFCI PROCTECTIONGFCI PROCTECTION Optional (Only type F) None Optional (Only type F) NoneOptional (Only type F) None WORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% load WORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% loadWORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% loadENVIRONMENT ENVIRONMENTENVIRONMENT WORKING HUMIDITY WORKING HUMIDITYWORKING HUMIDITY STORAGE TEMP., The MOISTURE STORAGE TEMP., The MOISTURESTORAGE TEMP., The MOISTURE 20% ~ 90% RH non-condensing 20% ~ 90% RH non-condensing20% ~ 90% RH non-condensing -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axesVIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes SAFETY STANDARDS SAFETY STANDARDSSAFETY STANDARDS UL458 (only for Type G ) UL458 (only for Type G )UL458 (only for Type G ) None NoneNone LVD NoneEN60950-1 LVD NoneEN60950-1LVD NoneEN60950-1 SAFETY AND EMC SAFETY AND EMCSAFETY AND EMC VOLTAGE RESISTANCE INSULATION RESISTANCE VOLTAGE RESISTANCE INSULATION RESISTANCEVOLTAGE RESISTANCE INSULATION RESISTANCE Bat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVAC Bat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVACBat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVAC Bat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH Bat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RHBat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH EMC EMISSION EMC EMISSIONEMC EMISSION EMC IMMUNITY EMC IMMUNITYEMC IMMUNITY Compliance to FCC class a None Compliance to FCC class a NoneCompliance to FCC class a None Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-MarkCompliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,4,5,6,8,11 Compliance to EN61000-4-2,3,4,5,6,8,11Compliance to EN61000-4-2,3,4,5,6,8,11 ACCHARGE CURRENT (Typ.) ACCHARGE CURRENT (Typ.)ACCHARGE CURRENT (Typ.) 25A 25A25A 12A6A 12A6A12A6A 25A 25A25A 12A6A 12A6A12A6A CHARGER CHARGERCHARGERSOLAR PANEL SOLAR PANELSOLAR PANEL The CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30A The CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30AThe CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30A CONTROL of WIRINGNote.7 RJ11 -RS232 CONTROL of WIRINGNote.7 RJ11 -RS232CONTROL of WIRINGNote.7 RJ11 -RS232 28.5 V 28.5 V28.5 V 45V 45V45V 57V 57V57V 75V 75V75V 14.3 V 14.3 V14.3 V 25V 25V25V 28.5 V 28.5 V28.5 V 45V 45V45V 57V 57V57V 75V 75V75V OTHER OTHEROTHER DIMENSION DIMENSIONDIMENSION 466.8*283.5*100 mm (L*W*H) 466.8*283.5*100 mm (L*W*H)466.8*283.5*100 mm (L*W*H) PACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFT PACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFTPACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFT NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage. NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage.NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage. 2.The output of the reduction capacity refers to curve1. 2.The output of the reduction capacity refers to curve1.2.The output of the reduction capacity refers to curve1. 3.De input, the reduction capacity refers to curve2. 3.De input, the reduction capacity refers to curve2.3.De input, the reduction capacity refers to curve2. 4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage. 4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage.4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage. 5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings. 5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings.5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings. 6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V. 6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V.6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V. 7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software. 7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software.7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software. 8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage. 8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage.8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage.File name:TN-3000-SPEC 2015-06-24 File name:TN-3000-SPEC 2015-06-24File name:TN-3000-SPEC 2015-06-24

제품 문서

데이터시트

기술 사양 및 성능 데이터

사용자 매뉴얼

설치 및 운영 가이드

Top