| 매개변수 | 가치 |
|---|---|
| 목 | Specifications |
| 케이블 | 0.2 mm26-core cabtyre cable, 2 m 6.562 ft long |
| 무게 | Net weight: 65 g approx., Gross weight: 110 g approx. |
| 세부 | Controller |
| 제품 | Electrostatic Sensor |
| 재료 | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Mode key: Acrylic, Jog switch: Heat-resistant ABS |
| 선형성 | plus or minus0.5 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be equal to the displayed values plus or minus5 %.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| 부품 번호 | EF-S1C |
| 제품명 | Electrostatic Sensor EF-S1 |
| 아날로그 출력 | Analog voltage• Output voltage: 1 to 5 V• Output impedance: 100 Ohm approx.(Note) In order to satisfy the linearity specifications for the analog output, do not use the judgment output. |
| 반복성 | plus or minus0.3 % F.S.(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode. |
| 제품 번호 | EF-S1C |
| 공급 전압 | 24V DC plus or minus10 % |
| 연장 케이블 | Extension up to total 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| 주변 습도 | 35 to 85 % RH, Storage: 35 to 85 % RH |
| 주변 온도 | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ – 4 to +158 ℉ |
| 현재 소비량 | Normal operation: 50 mA or less, ECO mode: 40 mA or less |
| 적용 가능한 센서 헤드 | EF-S1HS |
| 표시 범위(범위 모드) | –1,000 to 1,000 (plus or minus1 kV range mode)–1,999 to 1,999 (plus or minus2kV range mode)(Note) The display range (measurement range) is switched automatically when the measurement distance setting is changed at the controller. |
| 아날로그 출력:응답 시간 | 20 ms, 30 ms (STD), 110 ms, 210 ms, 410 ms, 810 ms switching method |
| 온도 특성 | 0.05 % F.S./℃(Note) F.S. is 2,000 V (–1,000 V to 1,000 V) for the plus or minus1 kV range mode and 4,000 V (–2,000 V to 2,000 V) for the plus or minus2kV range mode.(Note) The values given are for when the measured potential is plus or minus200 V or less in the plus or minus1 kV range mode and plus or minus400 V or less in the plus or minus2kV range mode.If the measured potentials are outside these values, the values will be 0.5 %/℃ of the displayed values. |
| 타이밍 입력 / 0 조정 입력 | NPN non-contact input• Signal conditionHigh: +V or open,Low: 0 to +2 V (source current 0.5 mA or less)• Input impedance: 10 kOhm approx. |
| 판단 결과 출력(OUT 1, OUT 2) | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: 30 V DC or less (between judgment output and 0 V)• Residual voltage: 1.5 V or less (at 100 mA sink current) |
| CE 마크 준수 지침 | EMC Directive, RoHS Directive |
| 판단 출력(OUT 1, OUT 2):응답 시간 | 10 ms, 20 ms (STD), 100 ms, 200 ms, 400 ms, 800 ms switching method |
| 판단 출력(OUT 1, OUT 2):출력 작업 | OUT1: +potential measurement output or window comparator outputOUT2: –potential measurement output or error output |
| 판단 출력(OUT 1, OUT 2): 단락 보호 | Incorporated |