| 매개변수 | 가치 |
|---|---|
| 목 | Specifications |
| 케이블 | 0.1 mm2 3-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long |
| 산출 | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| 무게 | Net weight (each emitter and receiver): 20 g approxGross weight: 50 g approx |
| 세부 | Thru-beam |
| 제품 | Threaded Miniature Photoelectric Sensor |
| 재료 | Enclosure: Die-cast zinc (Nickel plated)Lens: PolycarbonateEnclosure cover: Polycarbonate |
| 종범 | Nut: 2 pcsToothed lock washer: 2 pcs |
| 히스테리시스 | - |
| 보호 | IP67 (IEC) |
| 부품 번호 | EX-31A |
| 제품명 | Threaded Miniature Photoelectric Sensor EX-30 Ver.2 |
| 응답 시간 | 0.5 ms or less |
| 감지 범위 | 500 mm 19.685 in |
| 제품 번호 | EX-31A |
| 감지 대상 | dia. 2 mm dia. 0.079 in or more opaque object (Completely beam interrupted objects) |
| 공급 전압 | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| 연장 케이블 | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). |
| 주변 습도 | 35 to 85 % RH, Storage: 35 to 85 % RH |
| 방출 요소 | Red LED (modulated) |
| 오염도 | 3 (Industrial environment) |
| 충격 저항 | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| 주변 조도 | Incandescent light: 3,000 lx or less at the light-receiving face |
| 주변 온도 | -25 to +55 degrees -13 to +131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
| 현재 소비량 | Emitter: 10 mA or lessReceiver: 10 mA or less |
| 작동 표시기 | Orange LED (lights up when the output is ON)(incorporated on the receiver) |
| 안정성 지표 | Green LED (lights up under stable light received condition orstable dark condition, incorporated on the receiver) |
| 감도 조절기 | - |
| 진동 저항 | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (20 G max.) in X, Y and Z directions for two hours each |
| 절연 저항 | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| 출력:출력 작업 | Light-ON |
| 전압 내성 | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| 출력: 활용 범주 | DC-12 or DC-13 |
| CE 마크 지침 준수 | EMC Directive, RoHS Directive |
| 출력: 단락 보호 | Incorporated |
| 반복성(감지 축에 수직 방향) | 0.05 mm 0.002 in or less |
기술 사양 및 성능 데이터