| 매개변수 | 가치 |
|---|---|
| 목 | Specifications |
| PFHD | 6.6 × 10-9(Note) Probability of dangerous failure per hour. |
| 케이블 | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long |
| MTTFD | 100 years or more(Note) Mean time to dangerous failure. |
| 세부 | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
| 제품 | Compact Safety Light Curtain[Type4 PLe SIL3] |
| 재료 | Enclosure: Polycarbonate |
| 빔 피치 | 20 mm0.787 in |
| 부속품 | SF4B-TR25 (Test rod): 1 pc. |
| 부품 번호 | SF4B-H96CA-J05 |
| 제품명 | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
| ELCA 기능 | Incorporated (reducing mutual interference automatically) |
| 전력 전압 | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| 응답 시간 | OFF response: 14 ms or lessON response: 80 to 90 ms |
| 제품 번호 | SF4B-H96CA-J05 |
| 연장 케이블 | Extension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables |
| 음소거 기능 | Incorporated |
| 작동 범위 | 0.3 to 7m0.984 to 22.966 ft(Note) The operating range is the possible setting distance between the emitter and the receiver. |
| 방출 요소 | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
| 오염도 | 3 |
| 오버라이드 함수 | Incorporated |
| 보호 높이 | 1,943.4 mm 76.512 in |
| 인터록 기능 | Incorporated [Manual reset / Auto reset](Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
| 작동 고도 | 2,000 m6,561.68 ftor less(Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
| 선택적 기능 | Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing(Note) In case of using optional function, the handy-controller SFB-HC is required. |
| 주변 조도 | Incandescent light: 3,500 liter x or less at the light-receiving face |
| 최소 감지 객체 | ø25 mm ø0.984 in opaque object(Note) In case the blanking function is valid, the operation mode is changed. |
| 빔 채널 수 | 96 |
| 배출 정지 기능 | Incorporated |
| 보조 출력 음소거 | NPN open-collector transistor• Maximum sink current: 100 mA• Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable) |
| 유효 개구각 | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
| 적용 기준: 일본 | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3) |
| 적용 표준: 유럽 | EN 61496-1 (Type 4), EN ISO 13849-1:2015 (Category 4, PLe), EN 61508-1 to 3 (SIL3), EN 55011, EN 50178, EN 61000-6-2(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
| 제어 출력(OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 200 mA• Applied voltage: Same as supply voltage (between the control output and +V)• Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less• Maximum sink current: 200 mA• Applied voltage: Same as supply voltage (between the control output and 0 V)• Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable)• Leakage current: 0.1 mA or less (Including power supply OFF condition)• Maximum load capacity: : 0.22 micro F (No load to maximum output current)• Load wiring resistance: 3Ωor less |
| 적용 표준: 북미 | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06(Note) With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
| 외부 장치 모니터링 기능 | Incorporated |
| 보조 출력(비안전 출력) | PNP open-collector transistor / NPN open-collector transistor (switching method)• Maximum source current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and +V)• Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable)• Maximum sink current: 60 mA• Applied voltage: Same as supply voltage (between the auxiliary output and 0 V)• Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
| 대형 다목적 표시 기능 | Incorporated |
| 보조 출력 음소거: 작동 모드 | When muting auxiliary output: ON |
| 적용 가능한 규정 및 인증 | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification |
| 환경 저항성: 주변 습도 | 30 to 85 % RH, Storage: 30 to 85 % RH |
| 환경 저항성: 충격 저항성 | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
| 보조 출력 음소거: 보호 회로 | Incorporated |
| 순중량 (송신기와 수신기의 총합) | approx. 1,900 g |
| 적용 표준: 국제 표준 | IEC 61496-1 / 2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3) |
| 환경 저항성: 주변 온도 | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
| 환경 저항성: 보호 정도 | IP65 (IEC) |
| 환경 저항성: 진동 저항성 | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
| 환경 저항성: 절연 저항 | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| 제어 출력(OSSD 1, OSSD 2): 작동 모드 | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note) During muting, control output will not turn off even if the beams are interrupted.(Note) When the blanking function is enabled, the operating mode will change. |
| 제어 출력(OSSD1, OSSD2): 보호 회로 | Incorporated |
| 환경 저항성: 전압 내성 | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| 보조 출력(비안전 출력): 작동 모드 | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
| 보조 출력(비안전 출력): 보호 회로 | Incorporated |
| 현재 소비량: 대형 다목적 표시등이 켜집니다 | Emitter: 115 mA or lessReceiver: 155 mA or less |
| 현재 소비량: 대형 다목적 표시등 꺼짐 | Emitter: 105 mA or lessReceiver: 145 mA or less |
기술 사양 및 성능 데이터