| 매개변수 | 가치 |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| 즉 | AC |
| 비10디 | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| 목 | Specifications |
| 케이블 | UL style 2464, No.22 AWG 12-core |
| 무게 | Approx. 680 g |
| 제품 | Safety door switch with key |
| 재료 | Enclosure : PA66 |
| 보호 | IP 65 (IEC 60529) |
| 부품 번호 | SG-B2-K2AC-5 |
| 케이블 길이 | 5m16.404 ft |
| 제품명 | Safety door switch with key SG-B2 |
| 제품 번호 | SG-B2-K2AC-5 |
| 연동력 | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| 충격 저항 | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| 접촉 저항 | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| 연락처 정보 | |
| 작동 주파수 | 900 operations/hour |
| 적용 가능한 표준 | EN 60947-5-1, GS-ET-19 |
| 직접 개방력 | 80 N min. |
| 키 제거 위치 | A(removable in all positions) |
| 진동 저항 | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| 직접 개방 여행 | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| 전기적 내구성 | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| 기계적 내구성 | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| 열전류(Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| 적용 가능한 규정 | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| 유도 부하(AC-15) | - |
| 유도 부하(DC-13) | 2.3A |
| 액추에이터 작동 속도 | 0.05 to 1.0 m/sec. |
| 핵심: 직접 개방력 | 0.6 N・m min. |
| 범례: 주요 인장 강도 | 1.0 N・m min. |
| 범례: 직접 개방 각도 | 60°min. |
| 핵심: 기계적 내구성 | 100,000 operations min. |
| 정격 절연 전압(Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| 핵심: 핵심 작동 내구성 | 10,000 operations min. |
| 범례: 작동 사양 | 2 positions |
| 작동 조건: 고도 | 2,000 m6,561.68 ftmax. |
| 감전 보호 등급 | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| 단락 보호 장치 | Use 250 V / 10 A fast acting type fuse |
| 임펄스 내전압(Uimp) | 2.5 kV |
| 조건부 단락 전류 | 50 A (250 V) |
| 작동 조건: 주변 습도 | 45 to 85 % RH |
| 작동 조건: 오염도 | 3 (Inside 2) |
| 적용 표준: 사용 표준 | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| 작동 조건: 주변 온도 | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| 정격 동작 전압(Ue) / 정격 동작 전류(Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |