서비스 시간: 월요일 ~ 금요일 9:00-18:00
USQ4C11 - USQ4C11 SQ4-C11 PANASONIC Safety Controller, Control Category 4, Ple SIL3, safety liquid leak sensors can be..
재고 있음 인기 제품

USQ4C11

USQ4C11 SQ4-C11 PANASONIC Safety Controller, Control Category 4, Ple SIL3, safety liquid leak sensors can be..

$0.00USD
3985개 재고
주요 사양
목:Specifications
PFHD:When PNP output is selected: 1.89 × 10-9(when connecting 4 safety liquid leak sensors)When NPN output is selected: 1.80 × 10-9(when connecting 4 safety liquid leak sensors)
MTTFD:100 years or more
무게:Net weight: 170 g approxGross weight: 440 g approx
공급업체 정보
PANASONIC
PANASONIC
제품: 4316
보통 2-3 영업일 내에 발송됩니다
품질 보장
빠른 배송
기술 지원

기술 사양

매개변수가치
Specifications
PFHDWhen PNP output is selected: 1.89 × 10-9(when connecting 4 safety liquid leak sensors)When NPN output is selected: 1.80 × 10-9(when connecting 4 safety liquid leak sensors)
MTTFD100 years or more
무게Net weight: 170 g approxGross weight: 440 g approx
세부Controller
제품Safety Liquid Leak Sensor [Control Category 4 PLe SIL3]
재료Main unit case: PC + ABS (alloy)
함수Interlock / lockout cancel / Test input / External device monitor / Safety input / Control output polarity selection / Non-safety output polarity selection / Sensor connection number setting
보호IP20 (IEC) (However, it should be in IP54 protection structure of control panel)
부품 번호SQ4-C11
제품명Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4
전력 전압24 V DC+10-15 % Ripple P-P 10 % or less
잠금 출력OFF for lockout (Rating: Same as sensor monitor output)
제품 번호SQ4-C11
주변 습도35 to 85 % RH, Storage: 35 to 85 % RH
보조 출력Negative logic output of control output 1 / 2 (OSSD 1 / 2) (Rating: Same as sensor monitor output)[Auxiliary output ON when control output 1 / 2 (OSSD 1/2) is OFF]
주변 온도-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃-4 to +158 ℉
현재 소비량200 mA or less
적용 표준: 반도체Conforming to SEMI-S2-0310a
적용 기준: 일본JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3)
적용 표준: 유럽EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3)(Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate.
적용 기준: 대한민국S1-G-1, S2-W-5, KS C IEC 60947-5-2
제어 출력(OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor (switch method)[Selecting PNP output]- Maximum source current: 200 mA- Applied voltage: Same as power voltage (between control output to +V)- Residual voltage: 2.5 V or less (at 200 mA source current)[Selecting NPN output]- Maximum sink current: 200 mA- Applied voltage: Same as power voltage (between control output to 0 V)- Residual voltage: 2.0 V or less (at 200 mA sink current)
적용 표준: 북미ANSI/UL 508, CAN/CSA C22.2 No.14(Note) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD America, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL / ANSI standards.With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards.
적용 표준: 국제 표준ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
제어 출력(OSSD 1, OSSD 2):응답 시간20 ms or less (excluding the response time of the sensor)
제어 출력(OSSD 1, OSSD 2): 작동 모드ON when normal condition or initial detection, OFF when detection leakage or wrong installation
센서 모니터 출력(AUX1, 2, 3, 4, 비안전 출력)PNP open-collector transistor / NPN open-collector transistor (switch method)[Selecting PNP output]- Maximum source current: 60 mA- Applied voltage: Same as power voltage(between sensor monitor output to +V)- Residual voltage: 2.5 V or less (at 60 mA source current)[Selecting NPN output]- Maximum sink current: 60 m A- Applied voltage: Same as power voltage(between sensor monitor output to 0 V)- Residual voltage: 2.0 V or less (at 60 mA sink current)
센서 모니터 출력(AUX1, 2, 3, 4, 비안전 출력): 응답 시간100 ms or less (excluding the response time of the sensor)
제어 출력(OSSD 1, OSSD 2): 보호 회로(단락 보호)Incorporated
센서 모니터 출력(AUX1, 2, 3, 4, 비안전 출력): 작동 모드(출력 작동)ON when normal condition, OFF when initial detection or accidental leakage
센서 모니터 출력(AUX1, 2, 3, 4, 비안전 출력): 보호 회로(단락 보호)Incorporated

제품 설명

Safety Controller; Category 4, Ple SIL3; up to 4 safety sensors can be connected for liquid detection